WPI Liquid Biopsy Chip Snares Circulating Tumor Cells in Blood Drops from Cancer Patients
July 31, 2019 | Worcester Polytechnic InstituteEstimated reading time: 7 minutes
Researchers at Worcester Polytechnic Institute (WPI) have developed a chip made of carbon nanotubes that can capture circulating tumor cells (CTCs) of all sizes and types, and can do so with far greater sensitivity than existing technologies. The unique design of the device makes it possible to easily identify and even culture the captured cells, which could make it possible to detect early-stage tumors, predict the course of a cancer, and monitor the effects of therapy.
Details of the new technology are reported in the journal Lab on a Chip (Liquid biopsy using the nanotube-CTC-chip: capture of invasive CTCs with high purity using preferential adherence in breast cancer patients) by a team consisting of researchers at WPI, the Department of Neurological Surgery at the University of Massachusetts Medical School, and the James Graham Brown Cancer Center at the University of Louisville School of Medicine. Balaji Panchapakesan, professor of mechanical engineering at WPI, is the project lead.
High cancer mortality rates are largely attributable to tumors developing undetected until they reach advanced or inoperable stages, and to metastasis (when tumor cells travel through the bloodstream and initiate new tumors in other organs). Scientists have long sought a method that can reliably snare tumor cells as they travel through the bloodstream. Such technology could make it possible to detect cancers at very early stages, when treatment is more likely to be successful, and to spot the genetic changes that tumor cells undergo when a cancer is beginning to metastasize.
"Isolating CTCs with high purity is a significant challenge, akin to finding a needle in a haystack," Panchapakesan said. "These cells comprise as few as one to 10 cells among a billion blood cells, and the shedding of CTCs from tumors is a highly discontinuous process."
A number of research labs and companies have created so-called liquid biopsy devices, but the devices currently available have important limitations, Panchapakesan said. These include low sensitivity; the inability to trap CTCs of all sizes and types, or to capture clusters of CTCs along with individual cells; difficulty in retrieving captured cells from the devices for laboratory analysis; and high manufacturing costs. In addition, contamination of captured CTCs by white blood cells, which are similar in size to and can be mistaken for CTCs, is a problem for many liquid biopsy devices.
The device developed by Panchapakesan's team, described in the Lab on a Chip paper, has none of these limitations. The centerpiece of the device is a layer of carbon nanotubes that lines the bottom of a small well formed in a silicon/glass wafer. Panchapakesan says the chip design takes advantage of a natural tendency of CTCs to attach. "In order to travel to a distant site in the body and start a new tumor," he said, "CTCs need the ability to attach in an environment that is not conducive to attachment. In previous research, we have shown that they will attach preferentially to carbon nanotubes, but that white blood cells will not, by and large."
In addition, recent studies have shown that CTCs are far more fragile than previously believed and are subject to the environmental and mechanical stresses inherent in the blood stream. "These cells won't survive unless you give them a rocklike matrix to attach to--a softer matrix requires too much energy from the cell," Panchapakesan said.
"It's a medical problem at the intersection of mechanical engineering and biology," he said. "An understanding of the biology of cancer cells and how CTCs behave enabled us to design a mechanical engineering-based device."
The fact that white blood cells do not adhere to the nanotubes makes it possible to remove them from the chip, leaving the CTCs behind to be counted and identified. Red blood cells, which vastly outnumber the circulating tumor cells, also pose a problem. Since they tend to settle to the bottom of the chip, they could prevent CTCs from adhering to the nanotubes. The research team addressed this problem by lysing, or breaking up, the red blood cells before adding a blood sample to the chip. They found that the lysing process has no effect on the CTCs.
Tests of the chip using blood spiked with a known number of cancer cells tagged with fluorescent dye showed that it has a high sensitivity, with between 89 and 100 percent of cells in the test samples being captured. (The sensitivity of the chip increased the longer the blood remained in contact with the nanotubes.) Tests were also run with blood samples from actual breast cancer patients (stages 1-4) and yielded 100 percent sensitivity for detecting CTCs. CTCs were captured from all seven patient samples, while no tumor cells were captured from the samples from two healthy patients.
What's more, the chip captured individual CTCs exhibiting multiple phenotypes from early- and late-stage cancer patients, another potential advantage of the device. While other methods used to capture cells in other devices exhibit biases that prevent them from capturing the full range of cancer cell phenotypes, the WPI carbon nanotube chip appears to have the potential to do so.
Page 1 of 2
Suggested Items
Walmart Acquires Vizio, Set to Overtake Samsung as the Largest TV Brand in the US
02/22/2024 | TrendForceUS retail giant Walmart announced on February 20, that it has acquired smart TV brand Vizio for US$2.3 billion, aiming to accelerate the growth of its advertising business: Walmart Connect. Since its launch in 2021, Walmart Connect has seen double-digit annual growth in both its online and offline retail media advertising ventures. Vizio has been expanding its device ecosystem and its SmartCast TV OS, boasting over 18 million active users, according to TrendForce.
Fiber Optic Cables Effective Way to Detect Tsunamis
02/16/2024 | University of MichiganFiber optic cables that line ocean floors could provide a less expensive, more comprehensive alternative to the current buoys that act as early warning systems for tsunamis, says a University of Michigan researcher.
EIPC Winter Conference 2024, Day 2: A Closer Look at Global Trends
02/14/2024 | Pete Starkey, I-Connect007The opening session of the second day’s conference proceedings focused on global PCB trends and was introduced and moderated by Dr. Michele Stampanoni, vice president of strategic sales and business development at Cicor Group in Switzerland. He opened the session with Dr. Hayao Nakahara’s knowledgeable and enlightening video presentation on the IC substrates industry.
IDTechEx Discusses Whether Fuel Cell Vehicles Will Succeed and What It Would Take
02/12/2024 | PRNewswireThe sales of hydrogen fuel cell cars have largely stalled from 2021 onwards, but does this mean there is no market for fuel cell electric vehicles (FCEVs) in the future, and what is required to make them a success? IDTechEx's report, "
Electronics Industry Mourns Loss of Colleague and Visionary Michael Ford
01/31/2024 | I-Connect007Sadly, longtime I-Connect007 columnist, industry visionary, and friend Michael Ford passed away Jan. 27. “In this time of sorrow, we can take solace in the knowledge that Michael leaves a great legacy of contribution to the electronics industry,” according to a statement from Aegis Software. Michael was senior director of emerging industry strategy at Aegis. He was a prolific writer and speaker whose work and ideas put him at the forefront of electronics manufacturing. Working for Aegis gave him the opportunity to apply his software for electronics manufacturing experience to further drive technology solution innovation.