Conformal Coating Inspection Defects: Causes and Cures


Reading time ( words)

“Conformal coatings are increasingly used to protect electronic assemblies from contamination and corrosion in harsh or extreme environments, but correct selection and implementation is key to providing enhanced reliability.”

As a prelude to the three-day National Physical Laboratory/SMART Group Conformal Coating & Cleaning Experience, to be held during the National Electronics Week (NEW) conference and exhibition April 8-10, 2014 at the Birmingham, UK, National Exhibition Centre, NPL Defect Database Coordinator Bob Willis conducted a comprehensive and enlightening webinar entitled “Conformal Coating Inspection Defects: Causes and Cures,” which drew upon his many years of practical experience in solving process problems in the electronic assembly industry.

Stressing the importance of starting with clean surfaces before contemplating any conformal coating process, Willis reviewed the entire assembly operation with regard to the compatibility of PCB and component finishes, fluxes, soldering conditions, and cleaning chemistry. The solubility of flux residues in the chosen solvent was the most important factor is successful cleaning, and he recommended consideration of running costs, keeping the process as simple as possible, setting up a suitable monitoring process, and periodic reappraisal of the whole system. He listed a number of reference books and standards on cleaning and cleanliness testing.

After conducting a real-time poll of the cleaning techniques employed by webinar delegates, Willis moved on to the realities of conformal coating and discussed inspection and quality control methods, beginning with ways of measuring wet coating thickness. Simple wet depth gauges gave a reasonable indication, particularly if used to check the coating in two or three areas on a sample board, recording reading, location, material, and process parameters for future reference. For checking the uniformity of spray coating, he advocated coating a blank test board or a proprietary matrix test card and inspecting in UV light prior to running production. Dry coating thickness could be checked with a digital tester or focusing depth microscope, but a simple and effective test was to use peelable test labels and measure the change in their thickness with a micrometer.

It was important that specifications clearly defined areas to be coated, areas not to be coated and particularly areas where it did not matter, to avoid unnecessary rejection or rework. And it was useful to have a “golden board” for reference and to aid the set-up of AOI inspection.

Willis conducted a second real-time poll of the coating types favoured by delegates, then proceeded to discuss coating and cleaning defects. “Bug-eyes” was his term for defects resulting from a combination of air entrapment and too-rapid curing: Not giving the air time to escape. He considered that minor de-wetting or bubbles on non-critical areas such as substrate or package surfaces should not be a cause for rejection. And he used video to illustrate that small areas of apparent “de-wetting” were in fact simply sites where air bubbles had burst. However, the occurrence of such defects between terminations could have a serious impact on reliability if potentially corrosive materials were not fully encapsulated. It was important to determine whether the appearance of bubbling coincided with a change in process parameters such as wet coating thickness or curing rate.

 

Share




Suggested Items

The Data Format Effect on Business Costs

05/09/2022 | I-Connect007 Editorial Team
Nolan Johnson and Barry Matties talked with Axiom’s Rob Rowland and Kevin Bennett about current challenges facing EMS manufacturing. During this conversation, the pair discuss the impact of data file formats on pricing, manufacturing, and quality. As they explain, the use of intelligent data formats such as IPC-2581 and ODB++ can speed up the data import process compared to Gerber.

SMTA Atlanta: Peachy in the Peach State

04/27/2022 | Andy Shaughnessy, I-Connect007
I attended SMTA Atlanta Expo and Tech Forum last week, and it’s safe to say that this industry is definitely back in business in the Peach State. The aisles were busy all day, and the presentations were well attended.

How Smart Are You?

04/25/2022 | Michael Ford, Aegis Software Corp.
The standard IQ test has been established for many years now. Though the content within these tests has been cleverly and carefully put together, there are different kinds of “smarts” among people. It is likely that those who are putting together IQ tests will favor the kinds of “smarts” that they themselves have. Humans are very complex, however. Everyone is different, with natural skills and abilities in a multitude of disciplines: technical, artistic, social, and others. Put us all together as a society, and we make a pretty good team, at least when we all work together and support each other.



Copyright © 2022 I-Connect007. All rights reserved.